Eksempelprojekt, niveau 13

Transformermåling med solceller og netbeskyttelse

The distribution cabinet of an apartment building with an 88 kWp PV system, built from Hager univers parts: busbars with surge arrester and connection point zone, consumption and generation metering with NH1 fuse switch disconnectors on component modules, current transformers, voltage paths and meter cabinets with test terminal blocks, heat pump and inverter feeders, grid and system protection with voltage and frequency relay, buffered 24 V supply, fire brigade switch and a coupling switch with motor operator, undervoltage release and auxiliary switch built in; the cabinet comes with its plinth and lifting eyes.

Ark

Tegnet af SVG-eksporten i OpenECraft, sådan som projektet leveres.

18 sider

SideBeskrivelse
1.1Cover sheet
1.2Table of contents
1.3Single-line diagram
2.1Supply, surge protection and connection point zone
2.2Consumption metering
3.1Heat pumps and general consumers
4.1Coupling switch and NA protection relay
4.2Release, motor operator and fire brigade switch
5.1Generation metering
5.2Inverter feeders
6.1Mounting layout +HV
6.2Mounting layout +ZS1
6.3Mounting layout +ZS2
7.1Bill of materials
7.2Device list
7.3Terminal diagram
7.4Cable overview
7.5Panel legend

Flere eksempler

1 · Første kreds: trykknapper og lamper

Én diagramside med potentialerne +24V / 0V, trykknapper, en vælger, lamper og en sikring; artikler og styklisten.

Se eksemplet

2 · Relæ med selvhold

Start-/stopkreds med et relæ: spole og kontakter udgør én komponent med krydshenvisninger og kontaktbillede, klemrække, ledningsnumre, klemplan og forbindelsesliste.

Se eksemplet

3 · Stjerne-trekant-start

Hoved- og styrekreds på flere sider: hovedafbryder, motorværn, tre kontaktorer med forriglinger, tiltrækningsforsinket tidsrelæ, afbrydelsespunkter, potentialer med lederfarver, motorkabel og kabelrapporter.

Se eksemplet

4 · Transportbånd med PLC og tavle

Demoprojektet: PLC-ind- og udgange, tavlelayout med skinner, kabelkanaler og dørkomponenter, dørkabelbundt og motorkabel.

Se eksemplet

5 · Elektropneumatisk presse

Fluidteknik og el i ét projekt: pneumatikdiagram med luftbehandlingsenhed, ventilø, 5/2-ventiler, drøvlekontraventiler og cylindre; magnetspoler og positionsafbrydere er knyttet til ventilerne og cylindrene.

Se eksemplet

6 · Pumpestation med strukturbetegnelser

Anlægsstruktur efter IEC 81346 (funktioner og placeringer), sideafsnit, enstregsdiagram, en pumpe med direkte start og en med frekvensomformer, PLC-kort med digitale og analoge kanaler, et sensorstik og PLC-tildelingen.

Se eksemplet

7 · Revisioner, gennemgang og ændringsanmodninger

Transportbåndet efter den første frigivelse: en frigivet og låst revision, ændringer markeret siden, gennemgangskommentarer med rødmarkering, en ændringsanmodning, revision B i godkendelsesforløbet og en baseline at sammenligne med.

Se eksemplet

8 · Tavler på række

Pumpestationen bygget ind i to sammenbyggede gulvskabe: skinnesystem, skinner og kabelkanaler, dørkomponenter og greb, filterventilator, lys, PE-skinne, kabelforskruninger, en kabelgennemføring, klimaberegning, kanalfyldning og 3D-føring.

Se eksemplet

9 · Elrum

Tavlerækken i sit rum: L-formet plan, indervæg, dør og vindue, tavlerækken på sin plads, en skinne med en stikkontakt på en væg, en vægmonteret nødbelysning og en kabelbakke under loftet.

Se eksemplet

10 · Pumperum

Rummet med sammenbygningen og dens pumper: pumpemotorer forsynet gennem kabelforskruninger i skabenes tage, en pumpe og en tank på gulvet, kugleventiler og et manometer på væggen og vandkredsløbets DN25-rør ført i 3D langs et rørtracé på væggen.

Se eksemplet

11 · Building services with water supply and PV storage

A whole building in two rooms: the supply cable and the water main come in through building entries to the house connection box and the remote controlled valve; main distribution with busbars, Hager NH fuse switch disconnectors of three sizes and energy meters; cables and the water pipe pass a wall penetration into the technical room with PLC and pump cabinets, tanks and booster pumps, a compressor with air receiver and dryers and oilers at the outlets, a heat pump with buffer tank and hot water circulation, temperature, pressure and level sensors, a PV system with generator junction box, Victron MultiPlus-II and Inverter RS on the wall, Cerbo GX and Pylontech batteries in a 19-inch rack.

Se eksemplet

12 · Stik, benforbindelser og fladkabler

Stik med deres artikler: en sensor på M12 og en ventil på M8, en ventilator og dens termostat på GX16- og GX12-stik, en summer på et D-sub 9 og et betjeningspanel på et fladkabel mellem to IDC-bøsninger; stikvinduet viser benforbindelsen for hvert stik på dets stiksider med ledernes farver.

Se eksemplet

14 · Hovedtavle for lavspænding i en industrivirksomhed

Two bayed Hager univers cabinets: two aluminium supplies on busbar terminals for Al, transformer metering isolated by NH strips with solid links, a power analyser for the zero export of the battery storage, feeders on NH fuse switch disconnector strips of a 185 mm busbar system with current transformers clipped in behind them and energy meters on the Tree bus (DC charging station, sub-distributions, air conditioning), heat pumps behind residual current devices of type B, PV inverters and battery storage behind two coupling switches with motor operators, undervoltage releases and auxiliary switches, cable entry flanges for the large cables.

Se eksemplet

15 · Anlæg med bygninger, etager og et skakt

The pump room in a plant of two buildings: the main building with the electrical room on its ground level and the control room above, joined by a shaft; the pump house with pump motor 2, linked by a cable trench between the building entries through which its motor cable is routed; façade lights on the outside walls and a weather station on the roof.

Se eksemplet

16 · Kontorbygning med tag, trappe og installation

The plant of level 15 with an office building: the office on the ground level and the attic under a gable roof whose slopes cut its ceiling down to the knee wall, a stair turned at a quarter landing, roof windows in the front slope; Gira socket outlets, a network outlet and a switch, an MDT KNX push button and room temperature controller, a TV outlet at their mounting heights, a COSMO heating circuit manifold and a single-room control box.

Se eksemplet