OpenECraft 0.1.0
Released on 2026-11-04. Download the latest release
The first release: an electrical CAE editor for Windows, Linux, macOS and the browser, with a command line, an MCP server, a parts server and a project server.
- Schematics: device-oriented pages with live cross references and contact images, structure identifiers, page sections, macros with variants and a configurator; potentials, cables with cores and automatic wire, device and page numbering.
- Symbols: about 330 IEC 60617 symbols, NFPA / JIC, GB, GOST and JIS sets, fluid power (ISO 1219), P&ID, installation plans and single-line; a symbol editor.
- Terminals, plugs, PLC: multi-level terminals with accessories, plugs, PLC tag tables for TIA Portal, Studio 5000, TwinCAT, CODESYS and more, marker export.
- Connectors: the plug window shows the pin-out of a plug on the mating faces of both sides, coloured by the wires and cable cores at the pins (also as SVG export); connector parts for M5, M8, M12 (signal, fieldbus, Ethernet and power codings), M16, M23, M40, 7/8", GX aviation connectors, valve connectors, D-sub, DIN 41612, IDC, wire-to-board housings, pluggable terminal blocks, RJ11 / RJ12 / RJ45, BNC, heavy duty inserts, sealed connectors for mobile machines, CEE, appliance couplers, mains, installation, PV and battery connectors; pin layouts with inner rings, column numbering and free pin positions; ribbon and flat cables with a check of the cores on IDC connectors; example project 12 shows them.
- Reports and checks: live report pages, graphical terminal, cable and plug diagrams, drawn forms, a project check with message management and a check for open wire ends.
- Editor: an EPLAN-style ribbon that folds groups into menus when space is short, dockable panes per workspace with standard workspaces to return to their default arrangement, an Insert center, a properties pane, key tips, command search; unsaved changes are kept and asked for on every way out; released and locked pages are read only but selectable; crossing selection, zoom commands, contextual help (F1) and rebindable keys for every page action; pages and sections are dragged in the Pages navigator with a drop marker and the resulting name shown.
- Panel layout: devices at real size in 2D and 3D, virtual wiring with duct fill,
drilling and NC data, enclosure climate, line-ups, rooms and 3D routing; wiring and
mounting assistants for the workshop. In a room's floor plan cabinets turn in place,
cabinets in a bad place are drawn in the warning colour with the reason on hover,
inner walls end on the room walls, and the layout checks are shown below the view;
rooms and enclosures with content are deleted only after a question. Opening a project
analyses it in the background with a window showing the step and the route it is
at; the 3D routing searches several times faster and is kept while an edit changes
none of its routes; after an edit that does, it is searched in the background (the
status bar shows it, the 3D view keeps the earlier routes until then), so editing
a project with rooms no longer stalls the editor for seconds. Exports, reading 3D
model and parts files (STEP, IGES, Parasolid, EDZ, …) and the autosave run on another
thread too; the status bar shows what is running. Pipes and cables in a room keep to
its walls and ceiling instead of crossing it, and their bends keep the bend radius
apart. The 3D view is drawn by the graphics card (OpenGL 3 / WebGL 2, with a depth
buffer and anti-aliasing; Settings › Appearance switches it off), and drawn by the
processor it keeps what it shows between frames: large rooms turn smoothly. Moving in the
3D view: the wheel zooms at the pointer and walks on into a room, Shift+drag pans as the
right button does, a double-click turns the camera to what was clicked and closes in,
W A S D / the arrow keys and Q E move through it (Shift: faster), and a bar in the view
has the standard views (front, left, right, rear, top, isometric) and Fit (
Home). Devices without a 3D model of their own get a detailed, coloured one by what they are (pumps, vessels, valves, heat pumps, inverters, rack batteries, …); devices of the bundled catalogs (Victron, Pylontech, Hager, DEHN, Beckhoff, Phoenix Contact, Siemens) are drawn after their product photos and wired to their real terminals: the Pylontech batteries to the power terminals and ports on their front, the Victron devices from below, the Cerbo GX at its row of connectors, Beckhoff terminals at their spring contacts, surge arresters with the earth at the bottom, 19-inch devices at the rear; DIN rail models have a screw at every connection point; terminal blocks are drawn slice by slice with their stepped profile, wire entries, pushers or screws and marker fields (generic terminals, end covers and end brackets sized after Phoenix Contact PT, PTPOWER, D-ST, D-PT and CLIPFIX), between end plates and end brackets at both ends of every strip, and cable ducts with slotted walls and their cover; cables in the 3D routing end at the connection points their cores land on and part into their cores there; routes leave the devices they end at instead of running through them; the routes of a class are searched on several threads at once (with the same result), a selected cable or tube shows its properties like a wire with its cores and the connection points they join (picked in the 3D view and on the plate); a cabinet opened from its room is fitted into the view. The 3D view hides the walls in front of the camera or the ceiling on request; the opacity of the walls is a setting. Wires are drawn in their colours and, like cables and tubes, in their real thickness as round tubes bent round their corners with their bend radius, from the plate up to their connection points; cable cores are drawn with their cable. Routes keep half their thickness from what is around them and turn where their bends have room, cables keep out of cable ducts too small for them; View › Open cable ducts leaves out the covers of the ducts. Wires, cables and tubes that run together lie side by side, each on a lane of its own (in a cable duct packed in rows from its base, never over its cover), and where wires and cables pass through the wall of a duct its fingers are left out; where they would still run inside or through each other they are pushed apart, one over the other where they cross, inside the walls of their cabinet and out of its devices. Wires on one terminal or on terminals closer than they are thick leave them straight, side by side, instead of hooking round each other where they come out of a duct. The 3D view lays them out on another thread, several times faster, with a progress box while it does (it shows them as routed until then). Cables and tubes keep apart from each other in free air already when they are routed. A cable duct too small for its wires to lie side by side is an error of the project check. The fill level of a cable duct counts the cables and tubes routed through it as well as its wires, against the cross section inside the duct, also for the ducts on the walls, ceiling and floor of a room; cables and tubes keep out of the stretches of a duct they would fill above the limit. A cable ends a little before the device and its cores part from there in smooth curves, each coming into its connection point from the side its wires leave it; cables and wires run on through the cable glands, wall penetrations and cable passages between cabinets and rooms in one piece, bent round there; pipes and hoses end at the nozzles of the devices' models (suction and pressure nozzle of a pump, the nozzles of a vessel, both ends of a valve), coming straight out of them; a valve, meter or check valve in a pipe is taken as mounted with its inlet towards the pipe that feeds it. Cables through one gland pass it side by side; the cores of a cable are as thick as its diameter tells and part from their places round its axis. Wires in a cabinet without cable ducts leave their devices in the direction of their connection points and run round the rows of devices instead of behind or through them; wires leave their own devices over them, not through them. Wires, cables and pipes laid side by side are pushed at most a few times their thickness from their routes. The 3D routing measures the room around a route from the devices, walls, mounting plate, door and room walls themselves (thin busbars and rails between the cells of its grid included), so cables and pipes keep half their thickness from all of them, and from each other, everywhere: a route that cannot is not routed, and the project check reports it as an error that says to move its ends or make room for it. A route leaves its device, cable gland, nozzle or wall penetration straight on for its bend radius, runs two radii between two bends (the arcs of both fit between), turns only where its arc keeps clear of everything too, changes lanes with an S-bend (checked and drawn as one), and near its ends converges with the routes to the same end; the thickest cables of a class are routed first. In a cabinet a cable enters and leaves a cable duct through the slots of its walls, never through its base or its cover, lies in a duct over the rim of its walls and under its cover, and keeps half its thickness off the ducts it runs along outside them; in a 19-inch rack cables run along the space beside the mounting rails and leave it for their devices; in a room, running through the open space costs the more the farther from its surfaces, so cables and pipes keep close to the ceiling and the walls. The 3D view holds wires and cables in that band of a duct where they cross its walls (and leaves out the fingers they pass), cuts a duct's walls where another duct joins it, and brings a wire down before the next duct instead of into it through its cover, down beside the hinge of the door before the duct along the plate's edge, and straight through a cable passage for its bend radius on both sides. A cable takes the nearest cable gland whose clamping range fits it and that no other cable took, the thickest cables first, and a route whose way into its end runs beside it changes lanes into it with an S-bend. A connection takes the cross-section of a wire drawn with one at its connection point (a tap off a busbar) rather than the busbar's. Every wire, cable and tube has a least bend radius, a multiple of its thickness from the routing rules (wires and cables four times it, as laid fixed; hoses five times it or their own; pipes one and a half times it, a long-radius elbow), shown in the route and wire properties: the 3D view bends every corner with it, and corners too close for separate arcs as one smooth curve no tighter than it where the stretches around allow; wires through one cable passage pass it side by side, and two wires on one terminal leave it side by side. The wires of a room are routed in 3D between the devices on its walls (a room has no mounting plate to route them along); wires routed in 3D keep apart from the cables and from each other like cables do, outside the ducts and routing paths; cables and tubes are routed before the wires of a class; and a route comes up to another near its end only where that route is near one of its ends too (cables converging on one gland or terminal), not across its run. The 3D view keeps the wires and cables out of the walls, bases and covers of the cable ducts (crossing the walls where they are held above the rim), lays the cores of a cable where they part as they are and the rest clear of them, joins the legs of a route at a cable gland with the corner before it in line instead of a slanted run, and lets the cables of a rack run behind its 19-inch panels. A test of the editor checks that nothing drawn in the 3D views of the example projects clips anything: other wires, cables and pipes (beyond the overlap the layout leaves where they are packed: a millimetre and a half between wires, two and a half millimetres where a cable or pipe is involved), the ducts with their covers, the devices, the walls, plates and doors of the cabinets and the walls, floors and ceilings of the rooms. In the building example the incoming terminals of the main distribution feed the busbar they are mounted on, its feeder ducts are deeper, and the shunt sits between the first two Lynx distributors on the technical room's wall. A device standing on the floor of a room without connection points of its own is connected on top, where its terminal box is. Devices mounted on a busbar system are connected by its bars instead of wires. The title bar can show the frame time and the frames per second (Settings › Appearance). A placed device is shown in the panel layout or the 3D view from its context menu in the schematic. Pumps, tanks and other parts marked for floor mounting stand on the floor of a room; a pump or compressor without its own motor names its motor (property "Driven by") and is drawn coupled to it: through a shaft coupling (or a gear unit) in line, through V-belts (or a gear case) side by side, the motor turned towards it and raised on a riser. Pipe runs go on its walls, ceiling and floor, and hoses, pipes and cables are routed in 3D through the room and from its cabinets through their cable glands. Wall penetrations join neighbouring rooms: routes run from room to room through them (also through the rooms between), and the floor plan shows the rooms around the one shown, opened with a double-click. 19-inch racks (42 U in 2000 mm) have mounting rails instead of a plate; switches, patch panels, servers, UPS and blank panels snap onto whole rack units, with a rack elevation report and the commandsadd_rack,mount_in_rackandlist_racks. Building entries in outer walls bring the supply cable and the water main into the building: cables and pipes to devices outside the building are routed to them. Of several wall penetrations into the same room a route takes the nearest; cables and pipes ending at the same device (a heat pump) may meet there, also when the device is in a cabinet standing in the room: the cable comes in through the building entry and on through the cabinet's gland. Cabinets hanging on a wall are entered through the glands in their bottom too: a shaft below each gland, open to the front, stays free for the routes. A new enclosure system for house connection boxes (glass-fibre reinforced polyester with a hinged cover); in the building example the house connection box is such an enclosure above the cable entry, with the NH fuse base of the utility (fed from below) and the PEN terminal block inside, and a main earthing busbar beside it joins the PE busbar of the main distribution (main bonding conductor) and the foundation earth electrode, whose stainless steel lug comes out of the wall below it; the earth electrode is a new symbol. - Engineering: conductor sizing (
size_wiresgives the wires behind protective devices the cross-section they need; fuse switch disconnectors protect at the rating of their fuse links), short circuit and selectivity, load calculation, EMC, ISO 13849-1 safety functions; wire harnesses with KBL (their wires stay assigned when pages or symbols move), fluid power, pre-planning. Fluid power and P&ID symbols for air receivers, dryers, lubricators, quick couplings, heat pumps and buffer tanks, the media hot water and heating water; symbols for energy meters, PV generators, hybrid inverters, inverter / chargers, valve actuators and motor-operated valves. A device drawn pole by pole (fuse holders, surge arresters, fuse blocks) may have as many main functions as its parts provide. Symbols for the motor operator of a circuit breaker and the voltage and frequency relay of a grid and system protection (VDE-AR-N 4105). The voltage drop of a cable takes the rated current of the part providing the function it feeds (the motor operator, not the breaker it sits on). A fuse switch disconnector with solid links isolates only: no protection, no selectivity. Cable entry flanges are ways in for the 3D routing like cable glands. The checkbusbarsfinds busbar systems whose devices join more conductors than they have bars (a short circuit); the 3D view and the 3D exports draw each bar of a busbar system on its own, at the part's centre distance, on holders reaching just across the bars (their own solids in the 3D exports). A busbar terminal strip across the bars puts each terminal on its own bar. - Revisions and review: released pages, approval workflow, baselines with compare and merge, comments and redlining.
- Parts: a parts database with mounting data and 3D models (STEP, IGES, Parasolid,
JT, IFC), BMEcat, EPLAN XML and EDZ import; a parts server with a data portal that
shows the 2D front view and the 3D model of a part; the example parts, mounting
material included, come with both; the manufacturer catalogs of the parts server
(ABB, Beckhoff, DEHN, Hager with NH fuse switch disconnectors and energy meters,
MDT, Phoenix Contact, Pylontech, Siemens, Victron, Weidmüller) also feed the example
projects. Parts are dragged from parts management or the
data portal onto a schematic page, imported into the parts database on the way when
needed, and placed as a device with the part. Accessories that only work with other
parts (auxiliary and signal contacts, contact blocks) know the parts they fit from
either side, so one accessory serves many parts (the Hager CZ001 signal contact fits
the residual current devices CDA440D and CCA216D): the data portal and the parts
server show both directions, the device's Parts tab, the command line and the MCP
server offer the accessories that fit its parts, the project check reports an
accessory without such a part, and the panel layout and the 3D view mount them
beside or in front of their part with their own terminals. CSV, BMEcat and EPLAN XML
carry them; the building services example signals a tripped residual current
device through its CZ001. An accessory can also be a base the part stands on (the
univers N component module under an NH fuse switch disconnector: the device gets
its footprint and depth) or be built into the part (the undervoltage release and
the auxiliary switch of a circuit breaker: their terminals are on the breaker, and
their coils count as functions of the accessory, not as a second breaker). An
enclosure part delivered with its plinth (
Plinth: 200) gets it without a plinth part of its own. The Hager catalog adds the parts of a transformer-rated metering with PV: the univers cabinet FR25S2 with lifting eyes, component modules for the connection point zone, NH1 switches and transformers, LT153, HA354, SPA811Z, L73M, NBN116, MCN306, the h3+ breaker HNT161GR with motor operator, undervoltage release and auxiliary switch, the NA protection relay EU400, HTG911H, EZM100 and the meter cabinet FP62ZG2; example project 13 builds the distribution cabinet of an apartment building with them. Several of one base part lie side by side along the part (the current transformers clipped in behind the poles of an NH fuse switch disconnector strip). The Hager catalog adds the LVSG strips NH00 - NH3 for 185 mm busbar systems with the LVZW150 transformers and LVZVA-V aluminium terminals, the busbar terminal KS30C for Al cables, h3+ P630 HNW401DR with motor operator HXW042H, the residual current circuit breaker CDB640E (type B), the cabinet FR24H2 and the cable entry flange FZ402; new catalogsjanitza(UMG 604-PRO) andloxone(energy meter for 1 / 5 A transformers, Tree); example project 14 builds the main distribution of an industrial plant with them. - Data exchange: PDF, DXF / DWG, SVG; the panel as glTF, STEP, IGES, IFC, JT and Parasolid; ERP / PDM / PLM connectors and Autodesk Vault.
- Teams and automation: a project server with page locks, roles and Active Directory / LDAP sign-in; a command line, an MCP server for AI agents and plugins.
- Security: the servers check the token before they read a request's body, send
security headers with every answer, end sessions 30 days after the sign-in (sessions
of earlier versions end at once), count failed sign-ins per name and client address
so that nobody locks others out, and do not tell which user names exist. The data
portal page runs only its own script: files that can run scripts (SVG, XML) are
downloaded instead of shown and only web addresses become datasheet links. A
manufacturer user can no longer put parts into the catalog of another manufacturer.
Importing XML nested thousands of levels deep no longer crashes the parts server or
the editor, and archives unpacking to more than 1 GB are refused. On a project
server without token and accounts only its own machine creates users; reviewers
approve and comment in their own name only; managers of a project cannot lift the
denials of the administrators; anonymous callers cannot work under the name of an
account. Links of texts are opened and exported only for web and e-mail addresses.
The Vault and EPLAN clients send their token to their own server only, the MCP server
keeps its files in one folder (
OPENECRAFT_MCP_ROOT) and plugin programs are stopped after 5 minutes without answer. - Languages: English, German, French, Spanish and 16 more.
- Packages: Windows setup, deb, rpm, AppImage, Flatpak, snap, tar.gz, macOS disk
image and the web version. Every package, the web version included, carries the
license texts of OpenECraft and of the libraries and fonts it contains
(
THIRD-PARTY-LICENSES.html); release files come withSHA256SUMS. The EPLAN Data Portal is read with the personal access token of the EPLAN account only.